HEPA-CARE® HC600FUV Air Purification System
Mobile In-Room Air Purification System, with HEPA Filtration and Germicidal UV Disinfection, Converts any Room into a Negative Pressure Isolation Room Abatement Technologies® compact HEPA-CARE HC600FUV High Efficiency Air Purification System, with germicidal UV disinfection, is used to convert patient rooms into CDC-compliant negative pressure isolation rooms. This versatile system can also be operated as a continuous recirculating air purifier, to reduce potential exposure of patients and staff in high risk areas such as ER waiting and treatment areas, by lowering airborne pathogen counts. The 63 pound HC600FUV Patient Isolation System can typically maintain 12 air changes per hour (ACH) or more in rooms as large as 2,500-3,000 cubic feet. Hospital-grade, swivel casters make the unit highly mobile so that it can be rolled quickly to anywhere in the facility. Equipped with a Type A HEPA filter tested and certified to capture at least 99.99% of microscopic particles 0.3 microns in size, and a built-in germicidal UV lamp to irradiate and kill dangerous pathogens, the HC600FUV combines multiple air purification technologies in one exceptionally portable model. |
|
|
“Dirty” air laden with potentially infectious airborne organisms and harmful microscopic particles is first pulled through two filter stages:
UVGI Lamp Technology Sterilizes the AirThe air must also pass in close proximity to a high output UVGI disinfection lamp built into the HC600FUV HEPA filter that irradiates and destroys airborne virus and bacteria droplets, fungal spores and other micro-organisms. A safety interlock switch cuts off the lamp automatically when the filter access door is opened. Optional VAPOR-LOCK® Carbon Filters Remove Odors and GasesThe HEPA-CARE HC600FUV Air Purification System can also be equipped with an optional VAPOR-LOCK high-capacity, activated carbon or carbon blend filter to remove odors and gases. The VAPOR-LOCK filter replaces the standard 2” particulate pre-filter and must be ordered separately. Learn more about eliminating odors, vapors and VOCs from the air using VAPOR-LOCK high-capacity activated carbon and carbon blend filters.
|
|
The ultimate air purification solution combines 99.99% efficient HEPA air filtration with germicidal UV (UVGI) disinfection technology

Advanced engineering features of the HC600FUV include:
- Highly Portable - Narrow, upright cabinet mounted on four, built-in smooth-rolling swivel casters with two front foot brakes provide superior mobility and use in tight spaces
- Powerful Airflow - Energy-efficient motorized impeller rated for 100,000 hours of maintenance-free operation
- Unique Zero-Bypass Dual Cabinet Design - Added assurance that contaminated air can’t bypass the HEPA filter
- Aircraft-Type Powder-Coated Aluminum Cabinet - Durable .050” aircraft aluminum powder-coated white creates a professional-looking “hospital” appearance and is easy to decontaminate and maintain
- Safety Certification - Certified as a Class II Medical Devices under FDA 510K and NRTL certified to conform with relevant UL and CSA safety standards
- User-Friendly Controls - Microprocessor-based, password protected, touch pad controls.
- Export Version - 230 volt/50-60 Hz HC600FUVTF model is available for overseas customers
Click to download the HC600FUV Air Purification System brochure and additional information on our entire line of Air Purification Products for isolating infectious patients.
Click to determine the number of Portable Air Filtration Systems needed to produce the required air changes per hour (ACH), maintain negative pressure and effectively capture air contaminants.
Learn more about using germicidal UV-C disinfection lamps to supplement HEPA filtration.
View configuration animations to see how Abatement’s versatile HEPA-CARE Air Purification Systems can be used to create CDC and CSA-compliant patient isolation rooms and perform other infection control functions.
Read and learn the facts about true HEPA filtration and IEST (Institute of Environmental Sciences & Technology) manufacturing, testing and labeling requirements.
Click for more information on Nationally Recognized Testing Laboratory Product Safety Certification and why it is so important.
- Airflow* - Five airflow settings: 150-675 cfm
- Air Changes Per Hour - 12+ ACH @ 2,500-3,000 ft.3
- Net Weight with Filters - 63 pounds
- Shipping Weight - 70 pounds
- Dimensions (W x D x H) - 18”W x 19.75”D x 42.5”H
- Power Supply Requirements - 120 volts AC, 60Hz, 15 amps
- Energy Efficient - Operates at 225 watts or less
- UVGI Lamp - 39 watts total output; built into the HEPA filter assembly
- Electrical Safety - Certified as Class II Medical Devices under FDA 510K, and certified by Intertek Testing Services, an OSHA-accredited Nationally Recognized Testing Laboratory (NRTL), to comply with relevant UL and CSA safety standards
- Electronic Controls - Microprocessor-based, touch pad style with high-visibility color LCD, five preset airflow settings and secure password protection
- Cabinet Material - Durable .050” aircraft aluminum powder-coated white for ease of cleaning & disinfection
- Built-in Casters - Four easy-rolling casters with foot brakes
- Easy to Replace Filters - Hinged filter access door with flip latches & hex lock for secure access
- Filters :
- Pre-filter - 2” particulate pre-filter treated with an EPA-registered microbial growth inhibitor to protect against filter degradation (MERV 8)
- Pharmaceutical-grade HEPA Filter - Individually tested and certified in accordance with Institute of Environmental Sciences and Technology IEST-RP-CC001.3 to provide minimum filtration efficiency of 99.99% against a 0.3 micron challenge aerosol. Secure, closed-cell neoprene gasket seal to protect against contaminated air bypass
- Hospital-Grade Plug - 6’ white power cord with three prong plug
- Two Exhaust-Air Outlets - Top and rear air outlet grills with optional adapter for rear exhaust. One solid exhaust cover plate included
* Note: Use airflow ratings and air changes per hour (ACH) as a guideline only. Estimates are based on factory and independent testing @ 120 VAC with an air straightener and a traverse of readings taken with a computing vane-anemometer. Actual results may vary.
HEPA-CARE® Air Filtration
Systems: Performance & Specifications
Download
Printer Friendly Chart
AIRFLOW*: |
150 - 675 cfm |
150 - 675 cfm |
300 - 900 cfm |
PEAK AIR CHANGES PER HOUR (ACH): |
12 ACH in 2,500 - 3,000 ft3 |
12 ACH in 2,500 - 3,000 ft3 |
12 ACH in 3,500 - 4,000 ft3 |
ELECTRICAL REQUIREMENTS: |
120 volt/15 ampere/60 Hz single phase
|
120 volt/15 ampere/60 Hz single phase |
120 volt/15 ampere/60 Hz single phase |
NORMAL OPERATING AMPS: |
2.0 amps or less |
1.5 amps or less |
3.5 amps or less |
MOTORIZED IMPELLER: |
1 each motorized impeller with thermal overload protection, auto reset and designed for 100,000 hours of maintenance free operation. |
1 each motorized impeller with thermal overload protection, auto reset and designed for 100,000 hours of maintenance free operation. |
2 each motorized impellers with thermal overload protection, auto reset and designed for 100,000 hours of maintenance free operation. |
CABINETRY: |
.050” aluminum, powder coated white |
.050” aluminum, powder coated white |
.050” aluminum, powder coated white |
CABINET SEAMS: |
Assembled with solid rivets and sealed. |
Assembled with solid rivets and sealed. |
Assembled with solid rivets and sealed. |
CONTROL PANEL: |
Menu driven touch pad style, with LED lamps and liquid crystal display (LCD) screen, password protected. |
Menu driven touch pad style, with LED lamps and liquid crystal display (LCD) screen, password protected. |
Menu driven touch pad style, with LED lamps and liquid crystal display (LCD) screen, password protected. |
SOUND BAFFLE/
|
Yes |
Yes |
Yes |
CIRCUIT BREAKER: |
No |
No |
10 amp |
BUILT IN GROUND FAULT CIRCUIT INTERRUPTER (GFCI): |
Yes |
Yes |
Yes |
POWER INDICATOR LED: |
Yes |
Yes |
Yes |
FILTER LOADING INDICATOR LED: |
Yes |
Yes |
Yes |
MOTOR SPEED / AIRFLOW SETTINGS: |
5 motor speed settings |
5 motor speed settings |
5 motor speed settings |
POWER CORD: |
14/3 AWG cord with hospital grade plug |
14/3 AWG cord with hospital grade plug |
14/3 AWG cord with hospital grade plug |
EXHAUST OUTLETS: |
Top and/or back panel. Optional adapter available for rear exhaust. |
Top and/or back panel. Optional adapter available for rear exhaust. |
Top and back 12” x 8” grill with cover plate and solid grill cover plate. Optional exhaust collar available. |
FILTERS: |
|||
Stage 1 Pre-Filter |
Individually
tested and certified to a minimum efficiency of 99.99%, galvanized
steel frame and gasket seal. |
2”
pleated pre-filter treated with an EPA registered anti-microbial
agent (MERV 8). |
2”
pleated pre-filter treated with an EPA registered anti-microbial
agent (MERV 8). |
HEPA filter and HEPA filter/UV lamp assembly |
Individually
tested and certified to a minimum efficiency of 99.99%, galvanized
steel frame and gasket seal. |
Individually
tested and certified to a minimum efficiency of 99.99%, galvanized
steel frame and gasket seal. |
Individually
tested and certified to a minimum efficiency of 99.99%, anodized
aluminum frame and gel seal. |
HIGH-OUTPUT UVGI LAMP: |
39-watt germicidal lamp internally mounted within the HEPA filter assembly. |
n/a |
n/a |
OPERATIONAL SOUND LEVEL: |
52-58 dBA reading taken at 5 ft |
52-58 dBA reading taken at 5 ft |
47-59 dBA reading taken at 5 ft |
WEIGHT and DIMENSIONS: |
|||
Net Weight with Filters |
63 lbs. |
63 lbs. |
81 lbs. |
Overall Dimensions |
18”W x 19.75”D x 42.5”H |
18”W x 19.75”D x 42.5”H |
20.875”W x 20.5”D x 51”H |
*Airflow ratings are based on third party testing conducted @ 120 VAC with clean filters in accordance with generally accepted testing methods using highly accurate electronic flow measurement equipment. Different testing methods may produce higher or lower results. Ratings have been rounded off to the nearest 50 cfm for convenience. |
|||
Internally Mounted UVGI Germicidal Lamp
Powerful 39-watt UVGI lamp built-in to the HEPA filter irradiates and destroys harmful pathogens to sterilize the air as it is pulled through the HC600FUV.
High-Efficiency HEPA Filter
Abatement Technologies high-efficiency HEPA filters are individually tested and certified in accordance with Institute of Environmental Sciences and Technology IEST-RP-CC001.3 to provide minimum filtration efficiency of 99.99% against a 0.3 micron challenge aerosol. A strong anodized aluminum frame prevents warpage and will not support microbial growth. The unique closed-cell neoprene gasket provides a more secure seal than other designs to help prevent the bypass of contaminated air.
Quiet In-Room Operation
The powerful HC600FUV operates quietly in the background (52 dBA to 58 dBA @ 5’) purifying and sterilizing the air in patient rooms or other public spaces in hospitals and healthcare facilities. (HC600FUV shown in negative pressure mode exhausting HEPA-filtered air directly outdoors through the rear outlet grill and window.) View all versatile modes of operation and exhaust options.
Hinged Pre-Filter Access Door
for Rapid ReplacementHinged front door provides easy access to the
2” particulate pre-filter for replacement.

Converts Virtually Any Room
Weighing only 63 pounds, HC600FUV in-room patient air purification system, with built-in UV-C lamp, rolls quickly to convert virtually any room into a CDC-compliant negative pressure isolation room. The unit can also operate in continuous air cleaning and recirculation mode irradiating and sterilizing the air 24/7. (HC600FUV shown exhausting HEPA-filtered air through the top grill outlet manifold.) View all versatile modes of operation and exhaust options.

Slide-In Top Grill Manifold
Optional slide-in top grill manifold provides
air exhaust through the
top of the unit.

Flex Duct Locking Clamp
Optional 8” slide-in locking clamp shown connecting
flex duct to the optional
top grill outlet manifold (H2235-08).
Electronic Touch Pad Controls 
High-visibility, color LCD touch pad make the HC600FUV easy to use and control. Microprocessor-based electronics provide secure password protection and many user-friendly features including:
- Digital 4 x 20 LCD readout with backlit, alphanumeric color display
- Password protection
- Five airflow settings
- Menu-driven display for monitoring various operating parameters
- Increased reliability Green ‘Unit On’ LED that illuminates when the unit is powered
- Red ‘Change Pre-Filter’ LED that illuminates when the pre-filter
is loaded - Red ‘Change HEPA Filter’ LED that illuminates when the
HEPA is loaded - Backlit alpha-numeric display for status indication, setup and operating modes
- Modular design for ease of service
Safety Certified
Abatement HEPA-CARE units have been tested by Environmental Testing Laboratories (ETL), a Nationally Recognized Testing Laboratory (NRTL), and carry the ETL (U.S.) and ETLC (Canada) marks certifying that they comply with applicable OSHA, UL and CSA electrical safety standards. Filters meet UL900 flammability standards. Learn more about the importance of product safety certification in healthcare facilities.
Stocked HC600FUV Filters & Accessories Ready for Immediate Delivery
Filters |
||
|
|
2” Particulate Pre-Filter Treated with Microbial Growth Inhibitor: HC1802AM-12 (12 ea.) |
|
![]() |
Pharmaceutical-Grade HEPA Filter Assembly with Silicone-Gel Seal, Anodized Aluminum Frame and Built-In UVGI Germicidal Lamp: HC1612C-UV (1 ea.) |
|
Accessories |
||
|
HC2424-08 Ceiling Plate (1 ea.) |
|
![]() |
HC2448-08 Ceiling Plate (1 ea.) |
|
|
HC101ACCK Kit: Includes H2050-08-1 semi rigid ducting, H2235-08 slide in top manifold, H2350-08 locking clamp and H2240-08 quick connect collar (1 ea.) |
|
Related Products Frequently Bought TogetherCustomers who purchased the HEPA-CARE HC600UVF In-Room Air Purification System also bought one or more of the following related products: |
||
Room Air Pressure Monitors |
||
|
|
||
Germicidal UV Module |
||
|
||
Anteroom Modules |
||
|
|
HC7917 ANTE UP Inflatable Anteroom |
|


Quiet In-Room Operation