Abatement Technologies HEPA-CARE® Air Purification Systems can help convert standard patient rooms into CDC-compliant negative pressure or positive pressure Protective Environments (PE) and Airborne Infectious Isolation Rooms (AII) at a fraction of the cost of typical “design and build” methods. With far less facility disruption and the flexibility to relocate air filtration equipment to another room quickly, adding isolation wards or patient isolation surge capacity to new or existing facilities has never been easier.

Abatement Technologies HEPA-CARE Air Purification Systems.

 

Abatement Technologies HEPA-CARE Air Purification Systems.

Abatement Technologies HEPA-CARE Air Purification Systems.
Abatement Technologies HEPA-CARE Air Purification Systems.

Abatement HC600F and HC800F Models Abatement HC400C (top) and HC800C Ceiling Models

HEPA-CARE Air Purification Systems are user-friendly, functional and engineered to provide the highest level of micro-decontamination 24/7 at an economical price. These versatile, in-room units provide outstanding short-term and long-term patient isolation solutions by meeting CDC Guidelines for Infection Control in Healthcare Facilities using a range of negative or positive pressure modes of operation. Learn more about the advantages of negative pressure ‘inflow’ systems for infectious patient isolation.

Portable & Ceiling Mounted Operation

Abatement Technologies HEPA-CARE Air Filtration Systems are designed for portable or ceiling-mounted operation in hospitals and healthcare settings. Each unit is equipped with a certified Type A HEPA filter that traps and removes potentially hazardous microscopic particles with an efficiency of 99.99% at 0.3 microns. To remove odors and some volatile organic compounds (VOCs), HEPA-CARE systems utilize activated carbon filters. Optional germicidal UV-C disinfection modules irradiate and kill dangerous infectious pathogens.

Portable air purification models roll quietly to wherever you need them at a moments notice. Used for days, weeks or months at a time, these highly mobile units provide the greatest flexibility and can increase hospital surge isolation capacity planning cost-effectively.

Ceiling-mounted air purification models install flush with the ceiling grid and are the perfect choice for permanent patient isolation rooms. Ceiling mounted models are completely out of the way and offer the highest level of tamper-resistance.

Top

HEPA-CARE Features & User Benefits

Energy-Saving Motorized Impellers

All models are equipped with high efficiency motorized impellers that are quiet, lightweight and efficient. Compared to squirrel-cage type blowers, typical power consumption savings can be $500 or more per year when operated 24/7.

High Quality Metal-Frame HEPA Filters

Metal-frame filters are used instead of cheaper particleboard frames because they are stronger and won’t support microbial growth. Every completed filter is individually tested and certified, in accordance with Institute of Environmental Sciences and Technology IEST-RP-CC001.3 performance standards. All models are equipped with a Type G 99.99%-efficiency filter, with anodized-aluminum frames and silicone gel seals.

Carbon Absorption to Capture Airborne Gases & Vapors

High-capacity Vapor-Lock® activated carbon filters capture airborne gases, VOCs (volatile organic compounds) and odors. Vapor-Lock filters capture gasses and odors via a process known as carbon adsorption, whereby the gaseous molecules of the contaminants are attracted to and chemically bond to the surface of the carbon.

Aircraft-Type Cabinet Construction

Cabinets are constructed from a durable yet lightweight aircraft aluminum alloy, and then powder-coated for durability and ease of cleaning and decontamination. Solid aluminum-rivet fasteners and closed-cell neoprene gaskets ensure much stronger and more leak-resistant seams than hollow pop-rivets, sheet metal screws or nuts and bolts.

Tamper Resistant Control Panels and Filter Compartments

Controls panels and filter access compartments feature password protection or hex-lock latches to limit access and help prevent unauthorized tampering.

Attractive Design

With their high-tech appearance and white powder-coated cabinets, HEPA-CARE filtration units blend well into almost any hospital setting.

Password protected control panel.

Safety Certified

HEPA-CARE units have been tested by Environmental Testing Laboratories (ETL), a Nationally Recognized Testing Laboratory (NRTL), and carry the ETL (U.S.) and ETLC (Canada) marks certifying that they comply with applicable OSHA, UL and CSA electrical safety standards. Filters meet UL900 flammability standards. To learn more about the importance of product safety certification in healthcare facilities, click here.

Germicidal UV-C Disinfection

Abatement Technologies offers three HEPA-CARE germicidal UV-C modules for destroying airborne bacteria, viruses and fungi and neutralizing unpleasant odors. Equipped with the very latest in high-performance UVGI technology, these UV-C disinfection modules are designed to help facilities comply with the 2003 CDC and AIA Guidelines for Healthcare Infection Control in Airborne Infectious Isolation (AII) rooms and Protective Environment (PE) applications.

Versatile Modes of Operation

Abatement HEPA-CARE Air Purification Systems are engineered to operate 24/7 and can be installed in a number of configurations; with or without UV modules. Some examples:

 

Negative Pressue Isolation with Direct Outdoor Exhaust

 

Negative pressure mode with HEPA-filtered air exhausted directly outdoors through a window or wall:
The unit pulls in contaminated air, filters out contaminants and propels the filtered air outside the environment to negatively pressurize the room.
View the animation.

 

Negative pressure mode with the unit located inside of the isolation room

 

Negative pressure mode with HEPA-filtered air ducted into an exhaust duct above a drop ceiling:
The unit pulls in contaminated air, filters out contaminants and propels the filtered air outside the environment to negatively pressurize the room.
View the animation.

 

Negative pressure HEPA-Care {ortable & drop ceiling exhaust
*This option is for conversion of
existing patient rooms into patient isolation rooms
but should not be used for new facility
renovation or construction.

Negative pressure mode with HEPA-filtered air exhausted into a ceiling plenum:
In this configuration, filtered air from a portable unit in the room is ducted out the top exhaust port and into the plenum area above the drop ceiling. If a ceiling-mounted fixed model is used, the unit can simply exhaust out one or both of the exhaust grills directly into the space above the drop ceiling.
View the animation.

 

Recirculation Mode with HEPA-Care Portable & UV Module

Continuous air cleaning and recirculation:
The unit is located within the isolation room with no inlet or exhaust ducting, so there is no affect on room pressurization. This setup accelerates the removal rate of airborne contaminants and provides supplemental ACH equivalents.
View the animation.

 

50% negative pressure exhaust and 50% negative pressure:
Air is ducted to the outdoors from one outlet for negative pressure and recirculated into the room from the other. Running a HEPA-CARE unit in this configuration at high speed provides the ability to clean the air in some rooms up to 30 times per hour, without having to exhaust that much conditioned air from the building.
View the animation.

 

 

Positive Pressure Protective Isolation with HEPA-Care Unit & UV Module

 

Positive pressure:
HEPA-CARE Air Purification Systems can also be located within the room (as shown) or in an adjacent area to provide HEPA-filtered supply air and positive room-pressurization for Protective Environments and other sensitive areas.
View the animation.

 

Portable Air Filtration


HC800F Portable Model

This versatile and popular portable model can be rolled around the facility on its removable caster cart to convert any patient room into a negative-pressure isolation room. An upright, narrow-profile and lightweight design (about 90 lbs.) makes the HC800F easy to maneuver and fit into very tight spaces.

  • Variable airflow, 900 cfm maximum
  • One unit typically handles 3,500 to 4,200 cu. ft.
  • Electronic touch pad controls
  • Narrow-profile, upright design

Click for a brochure on our line of Portable HEPA-CARE Negative & Positive Pressure Air Purification Systems for Patient Isolation Rooms.
Click here for the Air Change Calculator.

HC800F Freestanding/Portable Model

 

Top

 

HC600F Freestanding/Portable Model

HC600F & HC600F-UV Portable Model

The HC600F is a smaller, less expensive and even lighter (63 lbs.) portable option to the HC800F. This model can typically provide 12 ACH in rooms as large as 2,500 to 3,000 cubic feet.

  • Variable airflow, 650 cfm maximum
  • 99.99% HEPA filtration
  • Electronic touch pad controls
  • HC600F-UV with UVGI germicidal lamp kills airborne bacteria and helps to neutralize odors

Click for a brochure on our line of Portable HEPA-CARE Negative & Positive Pressure Air Purification Systems for Patient Isolation Rooms.
Click here for the Air Change Calculator.

Top


New! Electronic Touch Pad Controls

The HC800F and HC600F portable air scrubbers now feature the industry’s only true electronic touch pad controls:

  • Digital 4 x 20 LCD readout with backlit, alphanumeric color display
  • Password protected
  • Five airflow settings
  • Menu-driven displays for monitoring various operating parameters
  • Increased reliability Green ‘Unit On’ LED that illuminates when the unit is powered
  • Red ‘Change Pre-Filter’ LED that illuminates when the pre-filter is loaded
  • Red ‘Change HEPA Filter’ LED that illuminates when the HEPA is loaded
  • Backlit alpha-numeric display for status indication, setup and operating modes
  • Modular design for ease of service

Top


Ceiling/Duct Mounted Air Filtration

HC800C Ceiling/Duct Mounted Model

The HC800C suspends in a 2 ft. x 4 ft. drop-ceiling panel, completely out of the way of patients and staff. It can be installed within the room to create negative pressure, or in an adjacent area to duct HEPA-filtered air and create positive pressure. Filters are room-side replaceable without having to disturb ceiling tiles.

  • Variable airflow, 750 cfm maximum
  • One unit typically handles 2,400 to 3,000 cu. ft.

 

HC800C Ceiling/Duct Mounted Model


Click for a brochure on our line of HEPA-CARE Ceiling/Duct Mounted Negative & Positive Pressure Air Purification Systems for Patient Isolation Rooms.
Click here for the Air Change Calculator.

Top

 

HC400C Ceiling/Duct Mounted Model

This single-speed model (variable speed option available) fits into a 2 ft. x 2 ft. drop ceiling panel. Like the HC800C, the HC400C can be used for negative and positive pressure, and is an ideal choice for applications where there is no floor space for a portable.

  • Variable airflow, 375 cfm maximum
  • One unit typically handles 1,500-1,800 cu. ft.
HC400C Ceiling/Duct Mounted Model

Click for a brochure on our line of HEPA-CARE Ceiling/Duct Mounted Negative & Positive Pressure Air Purification Systems for Patient Isolation Rooms.
Click here for the Air Change Calculator.

Top

 

Aspergillus fumigatus

Germicidal UV-C Disinfection Modules

Abatement Technologies HEPA-CARE germicidal UV-C (UVGI) disinfection modules irradiate and kill dangerous infectious pathogens. Each disinfection module is equipped with four ultra-high intensity lamps (156 watts total) that generate exceptionally high UV-C to clean and sterilize the air. Other powerful features include internal air baffles that slow the velocity of the airflow and ‘funnel’ it close to the lamps, thereby increasing the duration of microorganism exposure in the “kill zone.”

 

UV400C Ceiling Module

The UV400C ceiling module mounts conveniently into a 2’ by 2’ drop ceiling panel. It is designed to function as a standalone return air grill or supply air diffuser in rooms and other areas where air disinfection can be beneficial, but HEPA filtration is not required. Protective Environment (PE) applications for this model include patient waiting areas, ER, outpatient clinics, surgical centers and physician offices.

UV400C ceiling module

 

Features of the UV400C include:

  • Room-side lamp replacement via hinged access door
  • Electrical interlock instantly deactivates lamps when the access door is opened
  • Suspends into a 2’ x 2’ ceiling grid
  • Total UV-C output = 156 watts
  • UV intensity = 17,200 µ/cm2 @ 3” from lamps

Click for a brochure on our line of HEPA-CARE Germicidal UV-C Ceiling/Duct Mounted Negative & Positive Pressure Air Purification Systems for Patient Isolation Rooms.

Top

UV400C-PT Ceiling Module

UV400C-PT Ceiling Module

The UV400C-PT ceiling-mounted UV-C disinfection module is designed for use with Abatement ceiling-mounted HEPA-CARE HEPA filtration systems. This combination of HEPA plus UV-C provides an extra level of protection and security. It also provides additional assurances that highly toxic airborne microbial pathogens are contained in patient isolation and treatment rooms, ER triage rooms and other areas of potential exposure.

Features of the UV400C-PT ceiling module include:

  • Room-side lamp replacement via hinged access door
  • Electrical interlock instantly deactivates lamps when the access door is opened
  • Suspends into a 2’ x 2’ ceiling grid
  • Total UV-C output = 156 watts
  • UV intensity = 17,200 µ/cm2 @ 3” from lamps

Click for a brochure on our line of HEPA-CARE Germicidal UV-C Ceiling/Duct Mounted Negative & Positive Pressure Air Purification Systems for Patient Isolation Rooms.

Top

 

UV800F Portable UV Module

The UV800F is designed strictly for irradiating HEPA-filtered exhaust air from an HC800F portable HEPA-CARE model. This combination of HEPA filtration, negative pressure and UVGI disinfection is ideal for isolation rooms, ER, patient isolation during response to potential bioterrorism incidents or infectious illness outbreaks and during normal use. This combination is also perfect for disinfecting room air between patients.

UV800F Portable UV Module

The UV800F module installs easily onto the HC800F in just a few minutes. Simply slide it into the offset tabs of the clean air exhaust grill on top of the HC800F, and secure it in place with the included sheet metal screws. Once installed, there is typically no need to remove it.

Features of the UV800F include:

  • Fast, easy lamp replacement
  • Complete lamp shielding
  • Interlock instantly deactivates lamps if airflow is interrupted or module is removed from the HC800F
  • Total UV-C output = 156 watts
  • UV intensity = 17,200 µ/cm2 @ 3” from lamps

Click for a brochure on our line of HEPA-CARE Germicidal UV-C Ceiling/Duct Mounted Negative & Positive Pressure Air Purification Systems for Patient Isolation Rooms.
Click here to learn more about using germicidal UV-C disinfection lamps to supplement HEPA filtration.
Contact Us for pricing information or to ask questions about your application.

Top

Ante Up™ Inflatable Emergency Anteroom

The new Ante Up inflatable emergency anteroom from Abatement Technologies provides healthcare facility managers and contractors with a portable and faster alternative to erecting metal “frame and shroud” anteroom modules in the corridor. Ante Up quickly adds temporary anterooms to rooms wherever infectious, surge-capacity patients are isolated. When used in combination with HEPA-CARE® in-room HEPA filtration systems, Ante Up creates “clean to dirty” directional airflow.

Ante Up™ Inflatable Emergency Anteroom

Ante Up can be inflated and fully operational in less than five minutes. To minimize corridor obstruction, Ante Up can be placed within the doorway, or placed adjacent to the doorway, ready for use at a moment’s notice. Once deployed, the unit provides an unobstructed door opening up to 46-inches wide for workers and gurneys.

  • Takes up only 10” of corridor space when mounted within the door opening. Full-width door opening at gurney height
  • Portable unit & inflation compressor fit into a soft carrying case weighing less than 40 lbs. total
  • Fire-rated flame fabric
  • Reliable five year manufacturers warranty

Download the data sheet and learn more about the new portable Ante Up Inflatable Emergency Anteroom.

Top

Room Pressure Monitors

Differential pressure monitors from Abatement Technologies deliver precise, electronic measurement and documentation of room pressure testing 24/7. Why settle for periodic or once-a-day room pressure testing with manual smoke tubes? Abatement offers two electronic differential pressure models that provide automatic monitoring at a cost-effective price. Both units feature state-of-the-art digital electronics and touch pad controls with accuracy to 0.001" of water column. Products include:

  • The HCRPM-3N2K wall-mounted model
  • The HCPDPM portable model
HCRPM-3N2 Differential Pressure Monitor

HCRPM-3N2K Differential Pressure Monitor

This wall-mounted model continuously monitors and documents differential pressure conditions in both positive and negative-pressure environments. Compatible with Johnson Controls Metasys 3N2 building control systems, the HCRPM-3N2K room pressure monitor is a must for any permanent negative or positive pressure installation.

Click here for an HCRPM-3N2K Differential Pressure Monitor spec sheet.

Contact Us for pricing information or to ask questions about your application.

Top

 

HCPDPM Electronic Room Pressure Monitor

The portable HCPDPM model is often preferred by facilities using portable equipment that they move from room-to-room to set up temporary surge-capacity negative pressure or positive pressure isolation environments.

Click here for an HCPDPM Portable Differential Pressure Monitor product sheet.

Contact Us for pricing information or to ask questions about your application.

Click here for an isolation room monitor checklist.

HCPDPM Portable Differential Pressure Monitor

Top

Filters, Flex Duct & Other Accessories

[N]CASE Dust Control Awareness Barrier

[N]CASE® Dust Control Awareness Barrier

Reduce construction-related airborne infection risks in your healthcare facility by increasing awareness of dust control barrier standards. The [N]CASE product is superior because of its unique display of ICRA containment instructions and specifications printed directly on the product face, thereby increasing awareness of a construction zone, reducing risk and simplifying documentation requirements.

 

[N]CASE Dust Control Awareness Barrier specifications:

  • 6 mil. product thickness
  • Flame retardant
  • Used for negative or positive air pressure environments
  • Meets or exceeds ASTM-84 standards
  • ICRA containment instructions printed on product
  • Zipper attachment for easy pass-through

Contact Us or call us to receive detailed availability and pricing information.

 

  The [N]CASE product is superior.

 

Same Day or Next Day Shipment of Filters and Accessories.

 

Abatement Technologies stocks a complete inventory of replacement filters, flex duct, collars and other accessories and ancillary products for same or next day shipment.

Contact Us or call us to receive detailed accessory availability and pricing information.

 

Top

Need More Information?

Abatement Technologies experienced and knowledgeable sales consultants, customer service and technical support staff are ready to assist you with product recommendations to help keep your facility prepared and in compliance. Call us or Contact Us for a complete package of product information.

Click here for more information on HEPA-CARE Units and Bioterrorism.
Click here for more information on Isolating Pandemic Patients in Hospitals.
Click here for more information on the Infection Control Risk Assessment (ICRA) Matrix of Precautions for Construction and Renovation.

Note: Airflow & ACH ratings are based on peak airflow conditions in the recirculation mode, @ 120VAC input voltage, with clean filters & no external attachments. Filter loading and/or losses from inlet or outlet ducting, collars or lower input voltage can significantly reduce airflow & ACH.

 
 