HEPA-AIRE® PAS600 Portable Air Scrubber
All the Performance and Features of Heavier Units in a Compact Size

The advanced HEPA-AIRE PAS600 Portable Air Scrubber features:
- Powerful - High-efficiency airfoil blower. Provides 6 ACH @ 5,000-6,000 ft³
- Low Amperage - Daisy-chain multiple units on one 15 amp circuit
- Negative Pressure - Attached 8” diameter exhaust collar
- Easy-to-Transport - Top-mounted carrying handles and optional caster cart
- User-Friendly Controls - A complete array of convenient controls enables users to continuously monitor the operating status of the PAS600
- Safety Certified - ETL Certified for electrical safety
- Surface Protection - Large rubber bottom feet protect surfaces during use
- 230 VAC/50 Hz 0 - Export Model Available
Click to download the HEPA-AIRE PAS600 Portable Air Scrubber brochure. Download the features, performance and specifications for all HEPA-AIRE Portable Air Scrubber models.
Learn more about the importance of maintaining sufficient air changes per hour (ACH) and negative pressure to properly clean the air.
Learn more about true HEPA filtration and IEST (Institute of Environmental Sciences & Technology) manufacturing, testing and labeling requirements.
Click for more information on Nationally Recognized Testing Laboratory product safety certification and why it is so important.
Click for more information on the difference between tested ‘in-use’ airflow ratings versus meaningless ‘nominal’ or ‘free air’ blower ratings.
Click to determine the number of Portable Air Scrubbers needed to produce the required air changes per hour (ACH) for maintaining negative pressure and effectively capturing air contaminants.
Contact Us for more information about the PAS600 Portable Air Scrubber.
PAS6000 Portable Air Scrubber
- Airflow* - 200-600 cfm
- Air Changes Per Hour - 6 ACH @ 5,000-6,000 ft³
- Net Weight with Filters - 46 pounds
- Shipping Weight - 56 pounds
- Dimensions (L x W x H) - 28”L x 16.25”W x 17.5”H
- Power Supply Requirements - 120 VAC, 60Hz, 15 amps
- Electrical Safety - NRTL-certified to comply with UL Std. 507 & CAN/CSA Std. #C22.2 No. 113-M1984 for electrical safety
- Normal Operating Current - 2.5 amp maximum (daisy-chain multiple units on one 15 amp circuit)
- Motorized Impeller - Rated for 100,000 hours with thermal overload protection and auto reset
- Circuit Breaker - 12 amps
- Cabinet Material - 20 gauge stainless steel construction with solid, aircraft-type rivets
- Rubber Feet - Protect floors and secure the PAS600 firmly in place during operation
- Optional Caster Cart - Four-wheel caster cart that attaches to the base of the unit with 360° swivel front wheels
- Fast and Easy Pre-Filter Replacement - Tip-out pre-filter access door with full perimeter gasket seal protects against dirty-air bypass and provides fast filter change
- Filters:
- Stage 1 pre-filter - Inexpensive, high-capacity 1" FIBER-TRAPPER® 1.0 pre-filter for large particulates that can be washed & reused, or treated as a disposable (MERV 4)
- Stage 2 pre-filter - 2" pleated particulate pre-filter (MERV 6)
- Optional stage 3 pre-filter - 2" high-capacity VAPOR-LOCK® carbon filter for odor removal (MERV 7)
- Final stage - IEST compliant metal-frame, long-life HEPA filter with minimum efficiency of 99.97% @ 0.3 microns; does not rely on an electrostatic charge to maintain 99.97% HEPA efficiency
*Airflow ratings are based on third party testing conducted @ 120 VAC with clean filters in accordance with generally accepted testing methods using highly accurate electronic flow measurement equipment. Different testing methods may produce higher or lower results. Ratings have been rounded off to the nearest 50 cfm for convenience.
HEPA-AIRE® Portable Air Scrubbers: Performance & Specifications
Download
Printer Friendly Chart
AIRFLOW*: |
200 - 600 cfm |
150 - 900 cfm |
1,000 - 1,600 cfm |
700 - 2,100 cfm |
PEAK AIR CHANGES PER HOUR (ACH): |
6 ACH @ 6,000 ft3 |
6 ACH @ 9,000 ft3 |
6 ACH @ 16,000 ft3 |
6 ACH @ 21,000 ft3 |
ELECTRICAL REQUIREMENTS: |
120 volt/15 ampere/60 Hz
|
120 volt/15 ampere/60 Hz |
120 volt/15 ampere/60 Hz |
120 volt/15 ampere/60 Hz |
NORMAL OPERATING AMPS: |
2.5 amp draw or less @ 600 cfm. Multiple units daisy-chain on one 15 ampere circuit |
3.5 amp draw or less @ 1,000 cfm. Multiple units daisy-chain on one 15 ampere circuit |
10 amps or less |
12 amp draw or less |
BUILT-IN CIRCUIT BREAKER: |
12 amps |
10 amps |
15 amps |
15 amps |
MOTORIZED IMPELLER: |
255 watt motorized impeller w/thermal overload protection & auto reset & designed for 100,000 hours maintenance free operation |
400 watt motorized impeller w/thermal overload protection & auto reset & designed for 100,000 hours maintenance free operation |
1.75 hp blower w/thermal overload protection & auto reset |
1.5 hp motorized impeller w/thermal overload protection & auto reset & designed for 100,000 hours maintenance free operation |
CABINETRY: |
20 gauge stainless steel aircraft construction with solid rivets |
20 gauge stainless steel aircraft construction with solid rivets |
20 gauge stainless steel aircraft construction with solid rivets |
20 gauge stainless steel aircraft construction with solid rivets |
TRANSPORTABILITY: |
Two top lift handles or optional caster cart; multiple units stack and nest on a two-wheel dolly |
Two-wheel dolly consisting of 8” solid, non-marking rubber rear wheels, 360° swivel front caters and a secure top handle for easy movement & control |
Two-wheel dolly consisting of 8” solid, non-marking rubber rear wheels, 360° swivel front caters and a secure top handle for easy movement & control |
Built-in dolly with handle, 2 ea. 10” rear wheels with solid, non-marking rubber tires & 2 ea. 360° swivel casters in front |
SURFACE PROTECTION: |
Attached rubber feet |
Non-marking wheels and casters |
Non-marking wheels and casters |
Non-marking wheels and casters |
FILTERS: |
||||
Stage 1 Pre-Filter |
Inexpensive, high-capacity 1" FIBER-TRAPPER® 1.0 pre-filter for large particulates; can be washed & reused, or treated as a disposable (MERV 4) |
Inexpensive,
1” filter for capturing large particulates; can be washed & reused,
or treated as a disposable |
2”-deep FIBER-TRAPPER® 2.0 pre-filter (MERV 4) |
1”
coarse particulate pre-filter |
Stage 2 Pre-Filter |
2” pleated particulate pre-filter (MERV 6) |
2" pleated filter to capture medium-sized particulates (MERV 6) |
n/a |
2”
pleated particulate pre-filter |
Optional
Stage 2 |
2" high-capacity VAPOR-LOCK® carbon filter for odor removal (MERV 7) |
n/a |
2” pleated prefilter (MERV 6) or 2” VAPOR-LOCK® carbon filter (MERV 7) |
n/a |
Optional
Stage 3 |
n/a |
2" high-capacity
VAPOR-LOCK® carbon filter for odor removal |
n/a |
2" high-capacity
VAPOR-LOCK® carbon filter pack to remove odors
(MERV 7) or a second Stage 2 particulate pre-filter |
Final Stage HEPA Filter |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
INDIVIDUAL PRE-FILTER MOUNTING SHELVES |
No |
Yes |
Yes |
Yes |
WEIGHT and DIMENSIONS: |
||||
Net Weight with Filters |
46 lbs. |
85 lbs. |
138 lbs. |
170 lbs. |
Overall Dimensions |
28”L x 16.25”W x 17.5”H |
19.25”L x 22”W x 39”H |
21.5”L x 24.5”W x 45.5”H |
31.5”L x 25.25”W x 49.75”H |
ELECTRICAL CONTROLS: |
||||
Dual GFCI-Protected Receptacles |
Yes, for daisy-chaining multiple units per 15 or 20 amp circuit |
Yes, for daisy-chaining multiple units per 15 or 20 amp circuit |
No |
No |
Green “Power On” Visual Indicator Lamp |
Yes |
Yes |
Yes |
Yes |
Operating Hour Meter |
No |
Yes |
Yes |
Yes |
Speed Control Switch |
Variable |
Variable |
Two Speeds |
Two speeds |
*Airflow ratings are based on third party testing conducted @ 120 VAC with clean filters in accordance with generally accepted testing methods using highly accurate electronic flow measurement equipment. Different testing methods may produce higher or lower results. Ratings have been rounded off to the nearest 50 cfm for convenience. |
||||
Stackable Units
Multiple PAS600 units can be stacked to save time and space during use, transport and storage.

Easy HEPA Filter Access
Hinged door provides easy access and fast replacement of the HEPA filter.
Daisy Chain for More Cleaning Power
Multiple units can be daisy chained on a single 15 amp circuit for maximum air cleaning power.
Recessed Control PanelRecessed control panel helps to protect controls from accidental bumps. Control Panel Features:
|
|
![]() |
Abatement HEPA-AIRE Portable Air Scrubbers have been tested by Environmental Testing Laboratories (ETL), a Nationally Recognized Testing Laboratory (NRTL), and carry the ETL (U.S.) and ETLC (Canada) marks certifying that they comply with applicable OSHA and CSA electrical safety standards. Learn more about the importance of product safety certification in healthcare facilities. |
Stocked Filters & Accessories Ready for Immediate Delivery
Filters |
||
|
|
First Stage FIBER-TRAPPER® Particulate Pre-filter: F621-12 (case of 12 ea.) |
|
![]() |
Second Stage Particulate Filter: H502-6 (case of 6 ea.) |
|
![]() |
Optional Second Stage VAPOR-LOCK® Particulate/Carbon Filter: VL602-6 (case of 6 ea.), VL602 (1 ea.) |
|
![]() |
Optional Third Stage VAPOR-LOCK® High Capacity Activated Carbon Filter: VL1002-6 (case of 6 ea.), VL1002 (1 ea.) |
|
![]() |
Final Stage 99.97% HEPA Filter: H610C-99 (1 ea.) |
|
Accessories |
||
|
Inlet Manifold: MAN-PAS600 |
|
![]() |
Locking Clamp for Flex Duct Attachment: H2350-08 (1 ea.) |
|
![]() |
Optional Transport Cart: CART-PAS600 |
|
Flex |
||
|
Flex Duct: H2030-8 (8” diameter X 25’ long)A selection of 8” diameter flex duct materials and lengths are available. |
|
Related Products Frequently Bought Together
Customers who bought Abatement Technologies Portable Air Scrubbers also purchased one or more of the following related products:
Containment Barriers |
||
|
|
|
|
|
|
AIRE GUARDIAN® Mobile Containment Cube
|
|
|
|
ZipWall® Temporary Construction Barrier
|
|
![]() |
||
Additional Particle Control Products |
||
|
|
|
|
|
|
Mega-Pump Water Vacuum | |
|
|
|
|
|
|
|
|
|
|
||