HEPA-AIRE® PAS1800 Portable Air Scrubber
Replace Bulky Negative Air Machines with Quiet, Portable Airflow

Features of the HEPA-AIRE PAS1800 Portable Air Scrubber include:
- Easy to Transport - 8” rear wheels have smooth, non-marking tires to roll up or down stairs and protect against floor damage.
- Upright Design - Built-in two-wheel transport dolly with front swivel casters enables one person to tilt back the PAS1800 and move it almost effortlessly
- Highly Maneuverable in Tight Spaces - Front 360° swivel casters for “turning on a dime” in small spaces
- Powerful Airflow - 1,600 cfm (H)/1,000 cfm (L); creates up to 6 ACH @ 15,000 to 16,000 ft³
- User-Friendly Controls - Recessed control panel, two operating speeds and filter change indicator lamps
Click to download the HEPA-AIRE PAS1800 Portable Air Scrubber brochure with product specs. Learn more about the importance of maintaining sufficient air changes per hour (ACH) and negative pressure to isolate and contain airborne particles, odors and other contaminants.
Learn more about true HEPA filtration and IEST (Institute of Environmental Sciences & Technology) manufacturing, testing and labeling requirements.
Click for more information on Nationally Recognized Testing Laboratory product safety certification and why it is so important.
Click for more information on the difference between tested ‘in-use’ airflow ratings versus meaningless ‘nominal’ or ‘free air’ blower ratings.
Click to determine the number of Portable Air Scrubbers needed to produce the required air changes per hour (ACH) for maintaining negative pressure and effectively capturing air contaminants.
Contact Us for more information about the PAS1800 Portable Air Scrubber.
PAS1800 Portable Air Scrubber
- Rated Airflow* - 1,000-1,600 cfm
- Air Changes Per Hour - 6 ACH in areas up to 16,000 ft³
- Net Weight with Filters - 138 pounds
- Dimensions (L x W x H) - 21.5”L x 24.5”W x 45.5”H
- Power Supply Requirements - 120 VAC, 60Hz, 15 amps
- Normal Operating Current - 10 amps or less (safe for 15A circuits)
- Electrical Safety - NRTL-certified to comply with UL Std. 507 & CAN/CSA Std. #C22.2 No. 113-M1984 for electrical safety
- Motor - 1.75 HP
- Controls - Off/High/Low speed selector switch, separate amber ‘Replace Pre-filter’ and ‘replace HEPA’ lamps, hour meter
- Cabinet Material - 20 gauge stainless steel construction with solid, aircraft-type rivets
- Built-in Dolly - Two-wheel dolly with 8” solid, non-marking rubber rear wheels, 360° swivel front casters and a secure top handle for easy movement & control
- Easy to Replace Pre-Filters - Hinged and latched pre-filter access door with a full perimeter gasket seal to protect against dirty-air bypass
- Filters:
- Stage 1 - Inexpensive, 2”-deep FIBER-TRAPPER® 2.0 pre-filter for larger particulates (100+ microns); can be washed & reused, or treated as a disposable
- Optional stage 2 - Pleated, 2”-deep filter for medium-sized particulates (10-100 microns) or 2" VAPOR-LOCK® high capacity carbon filter specially designed to remove odors and vapors
- Final stage HEPA filter - Certified test efficiency of 99.97% or higher @ 0.3 microns, metal-frame
- Inlet Collar - Attached, 12” diameter
- Optional Exhaust Manifold - Slide-in metal exhaust manifold with 12” diameter collar
- Optional 12" Locking Clamps - Connects inlet and outlet exhaust manifolds to ducting
*Airflow ratings are based on third party testing conducted @ 120 VAC with clean filters in accordance with generally accepted testing methods using highly accurate electronic flow measurement equipment. Different testing methods may produce higher or lower results. Ratings have been rounded off for convenience.
HEPA-AIRE® Portable
Air Scrubbers: Performance & Specifications
Download
Printer Friendly Chart
AIRFLOW*: |
1,000 - 1,600 cfm |
700 - 2,100 cfm |
150 - 900 cfm |
200 - 600 cfm |
PEAK AIR CHANGES PER HOUR (ACH): |
6 ACH @ 16,000 ft3 |
6 ACH @ 21,000 ft3 |
6 ACH @ 9,000 ft3 |
6 ACH @ 6,000 ft3 |
ELECTRICAL REQUIREMENTS: |
120 volt/15 ampere/60 Hz |
120 volt/15 ampere/60 Hz |
120 volt/15 ampere/60 Hz |
120 volt/15 ampere/60 Hz
|
NORMAL OPERATING AMPS: |
10 amps or less |
12 amp draw or less |
3.5 amp draw or less @ 1,000 cfm. Multiple units daisy-chain on one 15 ampere circuit |
2.5 amp draw or less @ 600 cfm. Multiple units daisy-chain on one 15 ampere circuit |
BUILT-IN CIRCUIT BREAKER: |
15 amps |
15 amps |
10 amps |
12 amps |
MOTORIZED IMPELLER: |
1.75 hp blower w/thermal overload protection & auto reset |
1.5 hp motorized impeller w/thermal overload protection & auto reset & designed for 100,000 hours maintenance free operation |
400 watt motorized impeller w/thermal overload protection & auto reset & designed for 100,000 hours maintenance free operation |
255 watt motorized impeller w/thermal overload protection & auto reset & designed for 100,000 hours maintenance free operation |
CABINETRY: |
20 gauge stainless steel aircraft construction with solid rivets |
20 gauge stainless steel aircraft construction with solid rivets |
20 gauge stainless steel aircraft construction with solid rivets |
20 gauge stainless steel aircraft construction with solid rivets |
TRANSPORTABILITY: |
Two-wheel dolly consisting of 8” solid, non-marking rubber rear wheels, 360° swivel front caters and a secure top handle for easy movement & control |
Built-in dolly with handle, 2 ea. 10” rear wheels with solid, non-marking rubber tires & 2 ea. 360° swivel casters in front |
Two-wheel dolly consisting of 8” solid, non-marking rubber rear wheels, 360° swivel front caters and a secure top handle for easy movement & control |
Two top lift handles or optional caster cart; multiple units stack and nest on a two-wheel dolly |
SURFACE PROTECTION: |
Non-marking wheels and casters |
Non-marking wheels and casters |
Non-marking wheels and casters |
Attached rubber feet |
FILTERS: |
||||
Stage 1 Pre-Filter |
2”-deep FIBER-TRAPPER® 2.0 pre-filter (MERV 4) |
1”
coarse particulate pre-filter |
Inexpensive,
1” filter for capturing large particulates; can be washed & reused,
or treated as a disposable |
Inexpensive, high-capacity 1" FIBER-TRAPPER® 1.0 pre-filter for large particulates; can be washed & reused, or treated as a disposable (MERV 4) |
Stage 2 Pre-Filter |
n/a |
2”
pleated particulate pre-filter |
2" pleated filter to capture medium-sized particulates (MERV 6) |
2” pleated particulate pre-filter (MERV 6) |
Optional
Stage 2 |
2” pleated prefilter (MERV 6) or 2” VAPOR-LOCK® carbon filter (MERV 7) |
n/a |
n/a |
2" high-capacity VAPOR-LOCK® carbon filter for odor removal (MERV 7) |
Optional
Stage 3 |
n/a |
2" high-capacity
VAPOR-LOCK® carbon filter pack to remove odors
(MERV 7) or a second Stage 2 particulate pre-filter |
2" high-capacity
VAPOR-LOCK® carbon filter for odor removal |
n/a |
Final Stage HEPA Filter |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
INDIVIDUAL PRE-FILTER MOUNTING SHELVES |
Yes |
Yes |
Yes |
No |
WEIGHT and DIMENSIONS: |
||||
Net Weight with Filters |
138 lbs. |
170 lbs. |
85 lbs. |
46 lbs. |
Overall Dimensions |
21.5”L x 24.5”W x 45.5”H |
31.5”L x 25.25”W x 49.75”H |
19.25”L x 22”W x 39”H |
28”L x 16.25”W x 17.5”H |
ELECTRICAL CONTROLS: |
||||
Dual GFCI-Protected Receptacles |
No |
No |
Yes, for daisy-chaining multiple units per 15 or 20 amp circuit |
Yes, for daisy-chaining multiple units per 15 or 20 amp circuit |
Green “Power On” Visual Indicator Lamp |
Yes |
Yes |
Yes |
Yes |
Operating Hour Meter |
Yes |
Yes |
Yes |
No |
Speed Control Switch |
Two Speeds |
Two speeds |
Variable |
Variable |
*Airflow ratings are based on third party testing conducted @ 120 VAC with clean filters in accordance with generally accepted testing methods using highly accurate electronic flow measurement equipment. Different testing methods may produce higher or lower results. Ratings have been rounded off to the nearest 50 cfm for convenience. |
||||
Exceptionally Maneuverable
The upright design of the PAS1800 makes
it a much
more user-friendly upgrade from
larger and heavier negative air machines.
Built-in portability features include a convenient
transport dolly that
enables one person to tilt
back the unit and move it almost effortlessly
and noiselessly through the facility. 8” rear
wheels and front 360° swivel
casters provide
“turn-on-a-dime” maneuverability in tight spaces.
|
Recessed Control Panel Everything you need to operate the PAS1800 is conveniently located in one location. Control Panel Features:
|
|
|
|
|||
Stocked Filters & Accessories Ready for Immediate Delivery
Filters |
||
|
|
First Stage FIBER-TRAPPER® Particulate Pre-filter: F2221-12 (case of 12 ea.) |
|
![]() |
Optional Second Stage Particulate Filter: H502-6 (case of 6 ea.) or VL1002-6 (case of 6 ea.), VL1002 (1 ea.) |
|
![]() |
Final Stage 99.97% HEPA Filter: H1210C-99 (1 ea.) |
|
Accessories |
||
|
Locking Clamp for Flex Duct Attachment: H2350-12 (1 ea.) |
|
![]() |
Manifold (collar) for Flex Duct Attachment: PAS2012 (1 ea.) |
|
Flex |
||
|
Heavy Duty PVC Flex Duct: H2030-12
|
|
Related Products Frequently Bought Together
Customers who bought Abatement Technologies Portable Air Scrubbers also purchased one or more of the following related products:
Containment Barriers |
||
|
|
|
|
|
|
AIRE GUARDIAN® Mobile Containment Cube
|
|
|
|
ZipWall® Temporary Construction Barrier
|
|
|
|
||
Additional Particle Control Products |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||



Abatement
HEPA-AIRE Portable Air Scrubbers have been tested by Environmental
Testing Laboratories (ETL), a Nationally Recognized Testing
Laboratory (NRTL), and carry the ETL (U.S.) and ETLC (Canada) marks certifying that they comply with applicable OSHA and
CSA electrical safety standards. Learn more
about the importance of 