Features of the HEPA-AIRE PAS1200HC Portable Air Scrubber include:
- Easy to Transport - 8” non-marking rear wheels with smooth tires roll quietly and protect floors
- Powerful Blower - High-efficiency airfoil blower provides 6 ACH @ 7,500-9,000 ft³
- Maneuverable in Small Spaces - Front swivel casters allow the PAS1200HC to “turn on a dime” in tight spaces
- Solid-Rivet Aircraft Construction - Strong leak-resistant cabinets
- User-Friendly Controls - A complete array of convenient controls enables users to continuously monitor the operating status of the PAS1200HC
- Safety First - ETL/ETLc-certified to conform to UL507 and CSA 22.2 safety standards
- Easy 'No Tools' Pre-Filter Access - Fast filter changes
- Separate Pre-Filter Compartments - Less bypass, helps prevent premature HEPA loading
- 230 VAC/50 Hz Export Model - PAS1200TF runs on 230 Volt/50 Hz current (1,000-1,250 m³/hr.)
Click to download the HEPA-AIRE PAS1200HC brochure. Download the features, performance and specifications for all HEPA-AIRE Portable Air Scrubber models.
Learn more about the importance of maintaining enough Air Changes per Hour (ACH) and negative pressure to properly clean the air.
Learn more about true HEPA filtration and IEST (Institute of Environmental Sciences & Technology) manufacturing, testing and labeling requirements.
Click for more information on Nationally Recognized Testing Laboratory product safety certification and why it is so important.
Click for more information on the difference between tested ‘in-use’ airflow ratings versus meaningless ‘nominal’ or ‘free air’ blower ratings.
Click to determine the number of Portable Air Scrubbers needed to produce the required air changes per hour (ACH) for maintaining negative pressure and effectively capturing air contaminants.
Contact Us for more information about the PRED1200HC Portable Air Scrubber.
PAS1200HC Portable Air Scrubber
- Airflow* - 150-900 cfm
- Air Changes Per Hour - 6 ACH @ 9,000 ft³
- Net Weight with Filters - 85 pounds
- Shipping Weight - 95 pounds
- Dimensions (L x W x H) - 19.25”L x 22”W x 39”H
- Power Supply Requirements - 120 VAC, 60Hz, 15 amps
- Power Consumption - 3.5 amps or less
- GFCI-Protected Duplex Receptacle - Daisy-chain multiple units on one 15 amp circuit
- Motor/Blower - High-efficiency airfoil type motorized impeller rated for 100,000 hours, with thermal overload protection & auto reset
- Circuit Breaker - 12 amp pop-out style
- Electrical Safety - NRTL-certified to comply with UL Std. 507 & CAN/CSA Std. #C22.2 No. 113-M1984 for electrical safety
- Cabinet Material - 20 gauge corrosion-resistant stainless steel
- Cabinet Construction - Solid, aircraft-type rivets
- Built-in Dolly - Integral transport dolly with 8” rear wheels and solid, non-marking rubber tires, 360° swivel front casters and an ergonomic top handle for easy control and handling
- No Tools Pre-Filter Access - Hinged door secured by rotating latches, with full perimeter gasket seal to protect against bypass of contaminated air
- Pre-filter Mounting - Individual shelves for each pre-filter
- Filters -
- Stage 1 pre-filter - Inexpensive, 1" deep FIBER-TRAPPER® pre-filter for capturing large particulates; can be washed and reused or treated as a disposable (MERV 4)
- Stage 2 pre-filter - 2"-deep pleated prefilter (MERV 6)
- Stage 3 optional pre-filter - 2"-deep high-capacity VAPOR-LOCK® carbon filter for gas and odor adsorption (MERV 7)
- Final stage HEPA filter - IEST compliant metal-frame, HEPA filter with tested and certified minimum efficiency of 99.97% @ 0.3 microns
*Airflow ratings are based on third party testing conducted @ 120 VAC with clean filters in accordance with generally accepted testing methods using highly accurate electronic flow measurement equipment. Different testing methods may produce higher or lower results. Ratings have been rounded off to the nearest 50 cfm for convenience.
HEPA-AIRE® Portable Air Scrubbers: Performance & Specifications
Download
Printer Friendly Chart
AIRFLOW*: |
150 - 900 cfm |
700 - 2,100 cfm |
200 - 600 cfm |
PEAK AIR CHANGES PER HOUR (ACH): |
6 ACH @ 9,000 ft3 |
6 ACH @ 21,000 ft3 |
6 ACH @ 6,000 ft3 |
ELECTRICAL REQUIREMENTS: |
120 volt/15 ampere/60 Hz |
120 volt/15 ampere/60 Hz |
120 volt/15 ampere/60 Hz
|
NORMAL OPERATING AMPS: |
3.5 amp draw or less @ 1,000 cfm. Multiple units daisy-chain on one 15 ampere circuit |
12 amp draw or less |
2.5 amp draw or less @ 600 cfm. Multiple units daisy-chain on one 15 ampere circuit |
BUILT-IN CIRCUIT BREAKER: |
10 amps |
15 amps |
12 amps |
MOTORIZED IMPELLER: |
400 watt motorized impeller w/thermal overload protection & auto reset & designed for 100,000 hours maintenance free operation |
1.5 hp motorized impeller w/thermal overload protection & auto reset & designed for 100,000 hours maintenance free operation |
255 watt motorized impeller w/thermal overload protection & auto reset & designed for 100,000 hours maintenance free operation |
CABINETRY: |
20 gauge stainless steel aircraft construction with solid rivets |
20 gauge stainless steel aircraft construction with solid rivets |
20 gauge stainless steel aircraft construction with solid rivets |
TRANSPORTABILITY: |
Two-wheel dolly consisting of 8” solid, non-marking rubber rear wheels, 360° swivel front caters and a secure top handle for easy movement & control |
Built-in dolly with handle, 2 ea. 10” rear wheels with solid, non-marking rubber tires & 2 ea. 360° swivel casters in front |
Two top lift handles or optional caster cart; multiple units stack and nest on a two-wheel dolly |
SURFACE PROTECTION: |
Non-marking wheels and casters |
Non-marking wheels and casters |
Attached rubber feet |
FILTERS: |
|||
Stage 1 Pre-Filter |
Inexpensive,
1” filter for capturing large particulates; can be washed & reused,
or treated as a disposable |
1”
coarse particulate pre-filter |
Inexpensive, high-capacity 1" FIBER-TRAPPER® 1.0 pre-filter for large particulates; can be washed & reused, or treated as a disposable (MERV 4) |
Stage 2 Pre-Filter |
2" pleated filter to capture medium-sized particulates (MERV 6) |
2”
pleated particulate pre-filter |
2” pleated particulate pre-filter (MERV 6) |
Optional
Stage 2 |
n/a |
n/a |
2" high-capacity VAPOR-LOCK® carbon filter for odor removal (MERV 7) |
Optional
Stage 3 |
2" high-capacity
VAPOR-LOCK® carbon filter for odor removal |
2" high-capacity
VAPOR-LOCK® carbon filter pack to remove odors
(MERV 7) or a second Stage 2 particulate pre-filter |
n/a |
Final Stage HEPA Filter |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
True, non-electrostatic HEPA filter tested & certified to a minimum efficiency of 99.97% @ 0.3 microns |
INDIVIDUAL PRE-FILTER MOUNTING SHELVES |
Yes |
Yes |
No |
WEIGHT and DIMENSIONS: |
|||
Net Weight with Filters |
85 lbs. |
170 lbs. |
46 lbs. |
Overall Dimensions |
19.25”L x 22”W x 39”H |
31.5”L x 25.25”W x 49.75”H |
28”L x 16.25”W x 17.5”H |
ELECTRICAL CONTROLS: |
|||
Dual GFCI-Protected Receptacles |
Yes, for daisy-chaining multiple units per 15 or 20 amp circuit |
No |
Yes, for daisy-chaining multiple units per 15 or 20 amp circuit |
Green “Power On” Visual Indicator Lamp |
Yes |
Yes |
Yes |
Operating Hour Meter |
Yes |
Yes |
No |
Speed Control Switch |
Variable |
Two speeds |
Variable |
| *Airflow ratings are based on third party testing conducted @ 120 VAC with clean filters in accordance with generally accepted testing methods using highly accurate electronic flow measurement equipment. Different testing methods may produce higher or lower results. Ratings have been rounded off to the nearest 50 cfm for convenience. |
|||

Filters Pollutants Using up to Four Stages of Filtration
The PAS1200HC uses a special backward-curved blower and
high-speed motor
to pull pollutants through up to four
stages of filtration.
Recessed Control PanelThe recessed control panel provides all controls in one location. |
|
Control Panel Features:
|
|
![]() |
Abatement HEPA-AIRE Portable Air Scrubbers have been tested by Environmental Testing Laboratories (ETL), a Nationally Recognized Testing Laboratory (NRTL), and carry the ETL (U.S.) and ETLC (Canada) marks certifying that they comply with applicable OSHA and CSA electrical safety standards. Learn more about the importance of product safety certification in healthcare facilities. |
Stocked Filters & Accessories Ready for Immediate Delivery
Filters |
||
|
|
First Stage FIBER-TRAPPER® Particulate Pre-filter: F621-12 (case of 12 ea.) |
|
![]() |
Second Stage Particulate Filter: H502-6 (case of 6 ea.) |
|
![]() |
Optional Third Stage VAPOR-LOCK® High Capacity Activated Carbon Filter: VL1002-6 (case of 6 ea.), VL1002 (1 ea.) |
|
![]() |
Final Stage 99.97% HEPA Filter: H610C-99 (1 ea.) |
|
Accessories |
||
|
Locking Clamp for Flex Duct Attachment: H2350-10 (1 ea.) |
|
![]() |
Inlet/Exhaust Collar for Flex Duct Attachment: PAS680 |
|
Flex |
||
|
Flex Duct: H2030-10 (10” diameter X 25’ long)A selection of 10” diameter flex duct materials and lengths are available. |
|
Related Products Frequently Bought Together
Customers who bought Abatement Technologies Portable Air Scrubbers also purchased one or more of the following related products:
ICRA Packages |
||
Containment Barriers |
||
|
|
AIRE GUARDIAN® Mobile Containment Cube
|
|
|
|
ZipWall® Temporary Construction Barrier
|
|
|
|
[N]CASE® Dust Control Awareness Barrier |
|
Additional Particle Control Products |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
![]() |
||